KP/BB air curtains

KP/BB air curtains


Air curtains for doors and gates are used for protection against outdoor air intake at gates and  constructional holes and in doors  in  halls of industrial plants, storerooms, department stores  etc. .
They are fitted for deriving and heating air from outside a room. They may also be used without heating air as so called “cold” curtains.
The curtains are fitted for installation at gates at the height of 2÷6 m.
They may be positioned above gates or at the their sides.
Several curtains in a row may be used.

Product description


The curtains consist of:
   - housing made of galvanized sheet (with possibility of painting) with intake crack along the whole length
   - water or heater electric heater (only sizes 01, 02)
   - axial-flow fans (2,3,4 or 5)
The curtains are offered in two variants A and B, with five sizes in each. Each size of a curtain is manufactured in several lengths. B variant with increased spacing of fans and with less quantity of air is meant for milder conditions of the curtain operation.

Working conditions


The curtains allow for air speed at the floor within the limits of 2,5 ÷ 6 m/s.
The water heaters are supplied with water with the temperature of 150OC or lower and the pressure of up to 1,5MPa.

KP/BB-A-01-94-W

Parameters of fan in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Air flow of the curtain with the water heater

Air flow [m3/h]

2900

Thermal power [kW], outflow air temperature [OC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp [OC]

kW

OC

kPa

90/70

5

15,2

20

2,1

10

13,7

23

1,8

15

12,3

27

1,4

80/60

5

12,5

17

1,5

10

11,1

21

1,2

15

9,7

24

1,0

70/50

5

10,0

14

1,1

10

8,5

18

0,9

15

7,4

22

0,7

60/40

5

7,5

12

0,7

10

6,3

16

0,5

15

5,1

20

0,4

 

Operational noise level [dB(A)]

Noise level at distance of 3m

60

Curtain weight

Weight [kg]

47

KP/BB-A-01-94-W

KP/BB-A-01-94-E

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

2900

Thermal power levels [kW]

3 / 9 / 12

 

Operational noise level [dB(A)]

From distance of 1m

60

Curtain weight

Weight [kg]

47

KP/BB-A-01-94-E

KP/BB-A-01-94-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

Air flow [m3/h]

2900

 

Operational noise level [dB(A)]

From distance of 3m 60

Curtain weight

Weight [kg]

47

KP/BB-A-01-94-Z

KP/BB-A-01-141-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,13

 0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

4350

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

23,0

20

2,1

10

21,1

24

1,8

15

18,4

27

1,4

80/60

5

18,8

17

1,5

10

17,1

21

1,2

15

14,6

24

1,0

70/50

5

14,9

14

1,1

10

13,2

18

0,9

15

11,1

22

0,7

60/40

5

11,2

12

0,7

10

9,6

16

0,5

15

7,6

20

0,4

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

68

KP/BB-A-01-141-W

KP/BB-A-01-141-E

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

4350

Thermal power levels [kW]

6 / 12 / 18

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

68

KP/BB-A-01-141-E

KP/BB-A-01-141-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,13

0,12
Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

Air flow [m3/h]

4350

 

 

Operational noise level [dB(A)]

From distance of 3m 60

Curtain weight

Weight [kg]

68

KP/BB-A-01-141-Z

KP/BB-A-01-188-W

Parameters of fans in curtains

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

5800

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

30,6

20

2,1

10

27,6

23

1,8

15

24,6

27

1,4

80/60

5

25,1

17

1,5

10

22,3

21

1,2

15

19,5

24

1,0

70/50

5

20,2

14

1,1

10

17,3

18

0,9

15

14,7

22

0,7

60/40

5

15,0

12

0,7

10

12,6

16

0,5

15

10,2

20

0,4

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

89

KP/BB-A-01-188-W

KP/BB-A-01-188-E

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

5800

Thermal power levels [kW]

12 / 18 / 24

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

89

KP/BB-A-01-188-E

KP/BB-A-01-188-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

Air flow [m3/h]

5800

 

 

Operational noise level [dB(A)]

From distance of 3m 60

Curtain weight

Weight [kg]

89

KP/BB-A-01-188-Z

KP/BB-A-01-235-W

Parameters of fans in curtains

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

7250

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

39,2

20

2,1

10

35,3

23

1,8

15

31,5

27

1,4

80/60

5

32,2

17

1,5

10

28,5

20

1,2

15

25,1

24

1,0

70/50

5

25,5

14

1,1

10

22,2

18

0,9

15

18,9

22

0,7

60/40

5

19,3

12

0,7

10

16,1

16

0,5

15

13,2

20

0,4

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

110

KP/BB-A-01-235-W

KP/BB-A-01-235-E

Parameters of fans in curtain

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

7250

Thermal power levels [kW]

12 / 24 / 30

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

110

KP/BB-A-01-235-E

KP/BB-A-01-235-Z

Parameters of fans in curtain

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

Air flow [m3/h]

7250

 

 

Operational noise level [dB(A)]

From distance of 3m 60

Curtain weight

Weight [kg]

110

KP/BB-A-01-235-Z

KP/BB-A-02-110-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Moce cieplne kurtyny z nagrzewnicą wodną

Wydatek powietrza [m3/h]

4000

Moc cieplna [kW], temperatura powietrza wypływającego [oC]

oraz opory przepływu wody [kPa]

Parametry wody

[OC]

Temp. powietrza napływ. [OC]

kW

OC

kPa

90/70

5

26,1

23

6,0

10

23,5

27

4,8

15

21,0

30

4,0

80/60

5

21,5

20

4,2

10

19,1

23

3,3

15

16,7

27

2,6

70/50

5

17,2

17

2,8

10

14,8

20

2,2

15

12,6

24

1,8

60/40

5

12,9

14

1,8

10

10,8

17

1,3

15

8,8

21

1,0

 

Głośność pracy kurtyny [dB(A)]

Głośność z odległości 3m

62

Masa kurtyny

Masa [kg]

59

KP/BB-A-02-110-W

KP/BB-A-02-110-E

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

4000

Thermal power levels [kW]

6 / 12 / 18

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

59

KP/BB-A-02-110-E

KP/BB-A-02-110-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

Air flow [m3/h]

4000

 

 

Operational noise level [dB(A)]

From distance of 3m  62

Curtain weight

Weight [kg]

59

KP/BB-A-02-110-Z

KP/BB-A-02-165-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

6000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

39,3

23

6,0

10

35,4

27

4,8

20

31,6

30

4,0

80/60

5

32,3

20

4,2

10

28,7

23

3,3

15

25,1

27

2,6

70/50

5

25,7

17

2,8

10

22,3

20

2,2

15

19,0

24

1,8

60/40

5

19,5

14

1,8

10

16,3

17

1,3

15

13,3

21

1,0

 

Operational noise level [dB(A)]

From distance of 3m

61

Curtain weight

Weight [kg]

59

KP/BB-A-02-165-W

KP/BB-A-02-165-E

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

6000

Thermal power levels [kW]

9 / 18 / 27

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

84

KP/BB-A-02-165-E

KP/BB-A-02-165-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

Air flow [m3/h]

6000

 

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

84

KP/BB-A-02-165-Z

KP/BB-A-02-220-W

Parameters of fans in curtains

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

8000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

52,4

23

6,0

10

47,2

27

4,8

15

42,2

30

4,0

80/60

5

43,1

20

4,2

10

38,3

23

3,3

15

33,6

27

2,6

70/50

5

34,3

17

2,8

10

29,8

20

2,2

15

25,5

24

1,8

60/40

5

26,1

14

1,8

10

21,8

17

1,3

15

17,8

21

1,0

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

111

KP/BB-A-02-220-W

KP/BB-A-02-220-E

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

8000

Thermal power levels [kW]

12 / 24 / 36

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

111

KP/BB-A-02-220-E

KP/BB-A-02-220-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

Air flow [m3/h]

8000

 

 

Operational noise level [dB(A)]

From distance of 3m  62

Curtain weight

Weight [kg]

111

KP/BB-A-02-220-Z

KP/BB-A-02-275-W

Parameters of fans in curtains

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

10000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

65,5

23

6,0

10

59,1

27

4,8

15

52,8

30

4,0

80/60

5

53,9

20

4,2

10

47,9

23

3,3

15

42,0

27

2,6

70/50

5

42,9

17

2,8

10

37,3

20

2,2

15

31,8

24

1,8

60/40

5

32,5

14

1,8

10

27,3

17

1,3

15

22,3

21

1,0

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

137

KP/BB-A-02-275-W

KP/BB-A-02-275-E

Parameters of fans in curtain

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

10000

Thermal power levels [kW]

15 / 30 / 49

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

137

KP/BB-A-02-275-E

KP/BB-A-02-275-Z

Parameters of fans in curtain

Number of fans

5

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

Air flow [m3/h]

10000

 

 

Operational noise level [dB(A)]

From distance of 3m  62

Curtain weight

Weight [kg]

137

KP/BB-A-02-275-Z

KP/BB-A-1-120-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

6500

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

31,5

18

1,0

10

28,2

22

0,9

15

25,5

25

0,8

80/60

5

25,5

16

0,8

10

22,8

20

0,7

15

20,2

24

0,6

70/50

5

20,3

14

0,6

10

17,7

17

0,4

15

15,3

21

0,3

60/40

5

15,3

11

0,2

10

12,9

15

0,1

15

10,7

19

0,1

 

Operational noise level [dB(A)]

From distance of 5m

60

Curtain weight

Weight [kg]

102

KP/BB-A-1-120-W

KP/BB-A-1-120-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

Air flow [m3/h]

6500

 

 

Operational noise level [dB(A)]

From distance of 5m  60

Curtain weight

Weight [kg]

102

KP/BB-A-1-120-Z

KP/BB-A-1-180-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

9750

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

56,0

21

3,0

10

51,0

22

2,6

15

46,2

28

2,2

80/60

5

46,4

18

2,2

10

41,5

22

1,8

15

36,7

26

1,4

70/50

5

36,9

15

1,5

10

32,3

19

1,2

15

27,8

23

1,0

60/40

5

27,9

13

1,0

10

23,6

17

0,8

15

19,5

20

0,6

 

Operational noise level [dB(A)]

From distance of 5m

60

Curtain weight

Weight [kg]

102

KP/BB-A-1-180-W

KP/BB-A-1-180-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

Air flow [m3/h]

9750

 

 

Operational noise level [dB(A)]

From distance of 5m  62

Curtain weight

Weight [kg]

102

KP/BB-A-1-180-Z

KP/BB-A-1-240-W

Parameters of fans in curtains

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

13000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

84,8

23

7,5

10

77,1

27

6,8

15

69,5

30

6,0

80/60

5

69,9

20

6,0

10

62,6

23

4,4

15

55,4

27

3,5

70/50

5

55,7

17

3,5

10

48,7

20

3,0

15

42,0

24

2,3

60/40

5

42,3

14

2,3

10

35,8

18

1,8

15

29,2

21

1,4

 

Operational noise level [dB(A)]

From distance of 5m

60

Curtain weight

Weight [kg]

132

KP/BB-A-1-240-W

KP/BB-A-1-240-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

Air flow [m3/h]

13000

 

 

Operational noise level [dB(A)]

From distance of 5m  60

Curtain weight

Weight [kg]

132

KP/BB-A-1-240-Z

KP/BB-A-2-130-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

11000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

49,0

17

1,2

10

45,2

21

1,1

15

40,6

25

1,0

80/60

5

40,8

15

1,0

10

36,5

19

0,9

15

32,3

23

0,8

70/50

5

32,4

13

0,8

10

28,3

17

0,7

15

24,3

21

0,6

60/40

5

24,5

11

0,6

10

20,6

15

0,5

15

17,0

19

0,4

 

Operational noise level [dB(A)]

From distance of 5m

66

Curtain weight

Weight [kg]

88

KP/BB-A-2-130-W

KP/BB-A-2-130-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

Air flow [m3/h]

11000

 

 

Operational noise level [dB(A)]

From distance of 5m  66

Curtain weight

Weight [kg]

88

KP/BB-A-2-130-Z

KP/BB-A-2-195-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

16500

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

89,6

20

5,0

10

81,4

24

4,3

15

73,3

28

3,2

80/60

5

73,7

17

3,2

10

65,9

21

2,7

15

58,2

25

2,4

70/50

5

58,5

15

2,4

10

51,2

18

1,9

15

44,1

22

1,5

60/40

5

44,3

12

1,5

10

37,5

16

1,2

15

30,9

20

0,9

 

Operational noise level [dB(A)]

From distance of 5m

66

Curtain weight

Weight [kg]

129

KP/BB-A-2-195-W

KP/BB-A-2-195-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

Air flow [m3/h]

16500

 

 

Operational noise level [dB(A)]

From distance of 5m  66

Curtain weight

Weight [kg]

129

KP/BB-A-2-195-Z

KP/BB-A-2-260-W

Parameters of fans in curtains

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

22000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

125,8

21

11,5

10

114,2

24

9,3

15

103,0

28

8,0

80/60

5

103,0

18

8,0

10

92,6

22

7,6

15

81,8

25

5,5

70/50

5

82,3

15

5,5

10

72,0

19

4,5

15

62,1

23

3,8

60/40

5

62,4

13

3,9

10

52,7

16

2,6

15

43,5

20

2,0

 

Operational noise level [dB(A)]

From distance of 5m

66

Curtain weight

Weight [kg]

168

KP/BB-A-2-260-W

KP/BB-A-2-260-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

Air flow [m3/h]

22000

 

 

Operational noise level [dB(A)]

From distance of 5m  66

Curtain weight

Weight [kg]

168

KP/BB-A-2-260-Z

KP/BB-A-3-140-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

1,45

Revolutions [rpm]

1310

1330

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

15600

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Parametry wody

[OC]

Temp. powietrza napływ. [OC]

kW

OC

kPa

90/70

5

64,2

16

2,2

10

58,2

20

1,8

15

52,4

24

1,5

80/60

5

52,6

14

1,5

10

47,1

18

1,3

15

41,6

22

1,0

70/50

5

41,7

12

1,0

10

36,4

16

0,9

15

31,4

20

0,8

60/40

5

31,5

10

0,8

10

26,6

14

0,6

15

21,9

19

0,5

 

Operational noise level [dB(A)]

From distance of 5m

67

Curtain weight

Weight [kg]

105

KP/BB-A-3-140-W

KP/BB-A-3-140-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

 1,45

Revolutions [rpm]

1310

1330

Air flow [m3/h]

15600

 

 

Operational noise level [dB(A)]

From distance of 5m  67

Curtain weight

Weight [kg]

105

KP/BB-A-3-140-Z

KP/BB-A-3-210-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

1,45

Revolutions [rpm]

1310

1330

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

23200

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

115,0

19

8,0

10

104,6

23

6,1

15

94,2

27

5,3

80/60

5

94,6

16

5,2

10

84,6

20

4,3

15

74,8

24

3,3

70/50

5

75,1

14

3,1

10

65,7

18

2,7

15

56,6

22

2,2

60/40

5

56,8

12

2,2

10

48,0

16

1,6

15

39,6

20

1,2

 

Operational noise level [dB(A)]

From distance of 5m

67

Curtain weight

Weight [kg]

151

KP/BB-A-3-210-W

KP/BB-A-3-210-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

 1,45

Revolutions [rpm]

1310

1330

Air flow [m3/h]

23200

 

 

Operational noise level [dB(A)]

From distance of 5m  67

Curtain weight

Weight [kg]

151

KP/BB-A-3-210-Z

KP/BB-A-3-280-W

Parameters of fans in curtains

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

1,45

Revolutions [rpm]

1310

1330

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

31200

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

173,9

20

19,5

10

158,0

24

16,0

15

142,2

28

13,5

80/60

5

143,1

18

13,4

10

127,9

21

11,8

15

113,2

25

9,1

70/50

5

113,0

15

9,0

10

99,6

19

8,4

15

85,7

23

6,5

60/40

5

86,2

13

6,4

10

72,9

16

4,3

15

60,1

20

3,4

 

Operational noise level [dB(A)]

From distance of 5m

67

Curtain weight

Weight [kg]

199

KP/BB-A-3-280-W

KP/BB-A-3-280-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

 1,45

Revolutions [rpm]

1310

1330

Air flow [m3/h]

31200

 

 

Operational noise level [dB(A)]

From distance of 5m

 67

Curtain weight

Weight [kg]

199

KP/BB-A-3-280-Z

KP/BB-B-01-150-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

2900

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

23,0

27

3,8

10

20,8

30

3,0

15

18,5

33

2,5

80/60

5

19,1

23

2,6

10

16,9

26

2,0

15

14,8

30

1,7

70/50

5

15,1

19

1,7

10

13,2

23

1,4

15

11,2

26

1,2

60/40

5

11,5

16

1,3

10

9,6

19

0,8

15

7,9

23

0,6

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

65

KP/BB-B-01-150-W

KP/BB-B-01-150-E

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

2900

Thermal power levels [kW]

3 / 9 / 12

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

65

KP/BB-B-01-150-E

KP/BB-B-01-150-Z

Parameters of fans in curtain

Number of fans

4

Voltage [V]

230

400

Motor power [kW]

0,13

0,12

Current [A]

0,59

 0,29

Revolutions [rpm]

1400

1410

Air flow [m3/h]

2900

 

 

Operational noise level [dB(A)]

From distance of 3m

60

Curtain weight

Weight [kg]

150

KP/BB-B-01-150-Z

KP/BB-B-02-150-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

4000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

33,0

28

7,5

10

29,8

31

5,5

15

26,6

34

5,0

80/60

5

27,2

24

5,0

10

24,2

27

4,2

15

21,3

30

3,5

70/50

5

21,7

20

3,6

10

18,9

23

2,8

15

16,2

26

2,1

60/40

5

16,5

16

2,2

10

13,9

20

1,8

15

11,4

23

1,3

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

73

KP/BB-B-02-150-W

KP/BB-B-02-150-E

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

 

Thermal power and air flow of the curtain with the electric heaters

Air flow [m3/h]

 

4000

Thermal power levels [kW]

6 / 12 / 18

 

Operational noise level [dB(A)]

From distance of 3m

62

Curtain weight

Weight [kg]

73

KP/BB-B-02-150-E

KP/BB-B-02-150-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,20

0,18

Current [A]

0,9

 0,33

Revolutions [rpm]

1400

1350

Air flow [m3/h]

4000

 

 

Operational noise level [dB(A)]

From distance of 3m  62

Curtain weight

Weight [kg]

73

KP/BB-B-02-150-Z

KP/BB-B-1-200-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

6500

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

49,2

26

2,7

10

44,7

29

2,3

15

40,3

33

1,9

80/60

5

40,6

22

1,9

10

36,4

26

1,6

15

32,2

29

1,3

70/50

5

32,4

19

1,3

10

28,4

22

1,0

15

24,5

26

0,8

60/40

5

24,7

15

0,8

10

20,9

19

0,6

15

17,3

22

0,5

 

Operational noise level [dB(A)]

From distance of 5m

60

Curtain weight

Weight [kg]

102

KP/BB-B-1-200-W

KP/BB-B-1-200-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

Air flow [m3/h]

6500

 

 

Operational noise level [dB(A)]

From distance of 5m  60

Curtain weight

Weight [kg]

102

KP/BB-B-1-200-Z

KP/BB-B-1-300-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

9750

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

86,0

28

9,0

10

78,3

33

8,0

15

70,7

36

6,5

80/60

5

71,3

25

6,5

10

63,9

28

5,3

15

56,6

32

4,8

70/50

5

57,7

21

4,6

10

50,0

24

4,0

15

43,2

28

2,9

60/40

5

43,5

17

2,9

10

36,2

20

9,3

15

36,0

24

1,8

 

Operational noise level [dB(A)]

From distance of 5m

60

Curtain weight

Weight [kg]

149

KP/BB-B-1-300-W

KP/BB-B-1-300-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,31

0,28

Current [A]

1,35

 0,47

Revolutions [rpm]

1320

1250

Air flow [m3/h]

9750

 

 

Operational noise level [dB(A)]

From distance of 1m  60

Curtain weight

Weight [kg]

149

KP/BB-B-1-300-Z

KP/BB-B-2-200-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

11000

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

73,2

23

3,2

10

66,5

27

2,8

15

60,0

31

2,4

80/60

5

60,4

20

2,5

10

54,0

24

2,2

15

47,8

27

1,7

70/50

5

48,1

17

1,7

10

42,1

21

1,3

15

36,3

24

1,0

60/40

5

36,5

14

1,0

10

30,9

18

0,9

15

25,5

21

0,8

 

Operational noise level [dB(A)]

From distance of 5m

66

Curtain weight

Weight [kg]

117

KP/BB-B-2-200-W

KP/BB-A-2-196-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

Air flow [m3/h]

11000

 

 

Operational noise level [dB(A)]

From distance of 5m  66

Curtain weight

Weight [kg]

117

KP/BB-A-2-196-Z

KP/BB-B-2-300-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

16500

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

128,8

27

14,0

10

117,1

30

12,5

15

105,6

33

8,9

80/60

5

106,4

23

9,0

10

95,3

26

8,0

15

84,4

30

6,5

70/50

5

85,0

19

6,4

10

74,5

23

4,8

15

66,4

26

4,3

60/40

5

64,7

16

4,2

10

54,9

19

3,0

15

45,4

23

2,4

 

Operational noise level [dB(A)]

From distance of 5m

66

Curtain weight

Weight [kg]

170

KP/BB-B-2-300-W

KP/BB-B-2-300-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,61

0,54

Current [A]

2,8

 1,05

Revolutions [rpm]

1310

1360

Air flow [m3/h]

16500

 

 

Operational noise level [dB(A)]

From distance of 5m  66

Curtain weight

Weight [kg]

170

KP/BB-B-2-300-Z

KP/BB-B-3-200-W

Parameters of fans in curtains

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

1,45

Revolutions [rpm]

1310

1330

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

15600

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

88,9

21

5,1

10

80,8

24

4,0

15

72,8

28

3,4

80/60

5

73,2

18

3,3

10

65,5

22

2,8

15

57,9

25

2,4

70/50

5

58,2

15

2,4

10

50,9

19

1,9

15

43,9

23

1,6

60/40

5

44,1

13

1,5

10

37,3

17

1,4

15

38,0

20

1,0

 

Operational noise level [dB(A)]

From distance of 5m

67

Curtain weight

Weight [kg]

131

KP/BB-B-3-200-W

KP/BB-B-3-200-Z

Parameters of fans in curtain

Number of fans

2

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

 1,45

Revolutions [rpm]

1310

1330

Air flow [m3/h]

15600

 

 

Operational noise level [dB(A)]

From distance of 5m  67

Curtain weight

Weight [kg]

131

KP/BB-B-3-200-Z

KP/BB-B-3-300-W

Parameters of fans in curtains

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

1,45

Revolutions [rpm]

1310

1330

 

Air flow of the curtains with the water heater

Air flow  [m3/h]

23200

Thermal power [kW], outflow air temperature [oC]
and resistance of water flow [kPa]

Water temp.

[OC]

Inflow air temp. [OC]

kW

OC

kPa

90/70

5

156,0

24

19,0

10

142,2

27

15,5

15

128,2

31

13,0

80/60

5

129,0

20

13,0

10

115,4

24

11,6

15

102,2

27

9,0

70/50

5

102,0

17

8,9

10

90,0

21

8,0

15

77,7

24

6,1

60/40

5

78,1

14

6,1

10

66,1

18

4,2

15

54,6

22

3,3

 

Operational noise level [dB(A)]

From distance of 5m

67

Curtain weight

Weight [kg]

188

KP/BB-B-3-300-W

KP/BB-B-3-300-Z

Parameters of fans in curtain

Number of fans

3

Voltage [V]

230

400

Motor power [kW]

0,78

0,79

Current [A]

3,4

 1,45

Revolutions [rpm]

1310

1330

Air flow [m3/h]

23200

 

 

Operational noise level [dB(A)]

From distance of 5m  67

Curtain weight

Weight [kg]

188

KP/BB-B-3-300-Z

Files to download

KP/BB catalogue sheet pdf 23.06.2015 1,39MB